I initiated a Datapump Import job at 11am.It took almost 30minutes to load all the tables but 8 hours
later, the import log file shows that it's doing "Processing object type
SCHEMA_EXPORT/TABLE/INDEX/INDEX", so it means the import job has been hanging for almost 7.5 hours.
Check dba_resumable view to see when the suspension happened
SQL>select user_id,session_id, status, start_time, suspend_time,resume_time, error_msg from dba_resumable;
Check the error message.
My error message was;
Check dba_resumable view to see when the suspension happened
SQL>select user_id,session_id, status, start_time, suspend_time,resume_time, error_msg from dba_resumable;
Check the error message.
My error message was;
ORA-01691: unable to extend lob segment XXXXXXXX by value in tablespace XXX
Solution:
SQL>alter tablespace XXX add datafile '/YOUR_PATH/XXX02.dbf'size 20M AUTOEXTEND ON NEXT 10M MAXSIZE UNLIMITED;
You are good to go.
Good Stuff